Ad #600560 - Alia Electromagnetic Flowmeter-Flange Type,AMF900 Series
ALIAMAG AMF900 Series is a flange type Electromagnetic Flowmeter ideal for conductive liquids. It comes in sizes from 6 to 2000mm.
The AMF900 is widely used for tap-water, waste water, food & beverage Pulp & Paper and many other applications.
AMF900 Series magmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter
Website:http://www.alia-inc.com/
FEATURES
Various liner can be selected that satisfies most industrial applications.
Flow Velocity range:0-12 m/s, with good results for low flow applications
It comes any flanges such as ,ANSI, DIN, JIS ¡etc.
It excellent for high pressure application.
Protection class: IP68 is available,and the sensor can sink into the water.
FEP Liner suitable in vacuum tube.
High accuracy of +/-0.5% of reading(or+/-0.2% of reading)
With Forward/Reverse flowrate measure function.
SPECIFICATION
Pipe Size: 6 - 2000 mm(1/4" - 80")
Measureing Range:0 - 0.25 m/s min. 0-12 m/s max.
Material:Tube-Stainless Steel 304 Flange-Carbon Steel/Stainless Steel 304/Stainless Steel 316 Housing-Carbon Steel/Stainless Steel 304/Stainless Steel 316 Liner-PU/Neoprene/FEP/PTFE Electrode-316L/Hastelloy B,C/Titanium/Tantalum/Platinum/Tungsten Carbide
Connection:JIS 10K / JIS 20K / JIS 40K ANSI 150# / ANSI 300# / ANSI 600# DIN PN 10 / PN16 / PN25 / PN40
Accuracy:+/- 0.2 - +/- 0.5% of Reading
Max. Temperature: 180 Deg. C
Max. Pressure: 350 Kg/cm2
The AMF900 is widely used for tap-water, waste water, food & beverage Pulp & Paper and many other applications.
AMF900 Series magmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter
Website:http://www.alia-inc.com/
FEATURES
Various liner can be selected that satisfies most industrial applications.
Flow Velocity range:0-12 m/s, with good results for low flow applications
It comes any flanges such as ,ANSI, DIN, JIS ¡etc.
It excellent for high pressure application.
Protection class: IP68 is available,and the sensor can sink into the water.
FEP Liner suitable in vacuum tube.
High accuracy of +/-0.5% of reading(or+/-0.2% of reading)
With Forward/Reverse flowrate measure function.
SPECIFICATION
Pipe Size: 6 - 2000 mm(1/4" - 80")
Measureing Range:0 - 0.25 m/s min. 0-12 m/s max.
Material:Tube-Stainless Steel 304 Flange-Carbon Steel/Stainless Steel 304/Stainless Steel 316 Housing-Carbon Steel/Stainless Steel 304/Stainless Steel 316 Liner-PU/Neoprene/FEP/PTFE Electrode-316L/Hastelloy B,C/Titanium/Tantalum/Platinum/Tungsten Carbide
Connection:JIS 10K / JIS 20K / JIS 40K ANSI 150# / ANSI 300# / ANSI 600# DIN PN 10 / PN16 / PN25 / PN40
Accuracy:+/- 0.2 - +/- 0.5% of Reading
Max. Temperature: 180 Deg. C
Max. Pressure: 350 Kg/cm2